Salicru SPS One 700VA V2 SAI & Network UPS Tools (NUT)

He comprado este SAI/UPS al ser compatible con GNU/Linux gracias al proyecto NUT (Network UPS Tools).

Dejo a continuación mis archivos de configuración incluyendo toda la documentación comentada que viene incluida en estos ya que es donde se explica todo lo referente a las distintas opciones de configuración, y ante cualquier duda me comentáis.

# Network UPS Tools: example nut.conf
#
##############################################################################
# General section
##############################################################################
# The MODE determines which part of the NUT is to be started, and which
# configuration files must be modified.
#
# This file try to standardize the various files being found in the field, like
# /etc/default/nut on Debian based systems, /etc/sysconfig/ups on RedHat based
# systems, ... Distribution's init script should source this file to see which
# component(s) has to be started.
#
# The values of MODE can be:
# - none: NUT is not configured, or use the Integrated Power Management, or use
#   some external system to startup NUT components. So nothing is to be started.
# - standalone: This mode address a local only configuration, with 1 UPS 
#   protecting the local system. This implies to start the 3 NUT layers (driver,
#   upsd and upsmon) and the matching configuration files. This mode can also
#   address UPS redundancy.
# - netserver: same as for the standalone configuration, but also need
#   some more network access controls (firewall, tcp-wrappers) and possibly a
#   specific LISTEN directive in upsd.conf.
#   Since this MODE is opened to the network, a special care should be applied
#   to security concerns.
# - netclient: this mode only requires upsmon.
#
# IMPORTANT NOTE:
#  This file is intended to be sourced by shell scripts.
#  You MUST NOT use spaces around the equal sign!

MODE=standalone
# Network UPS Tools: example ups.conf
#
# --- SECURITY NOTE ---
#
# If you use snmp-ups and set a community string in here, you 
# will have to secure this file to keep other users from obtaining
# that string.  It needs to be readable by upsdrvctl and any drivers,
# and by upsd.
#
# ---
#
# This is where you configure all the UPSes that this system will be
# monitoring directly.  These are usually attached to serial ports, but
# USB devices and SNMP devices are also supported.
#
# This file is used by upsdrvctl to start and stop your driver(s), and
# is also used by upsd to determine which drivers to monitor.  The 
# drivers themselves also read this file for configuration directives.
#
# The general form is:
# 
# [upsname]
#       driver = <drivername>
#         port = <portname>
#	< any other directives here >
#
# The section header ([upsname]) can be just about anything as long as
# it is a single word inside brackets.  upsd uses this to uniquely 
# identify a UPS on this system.
#
# If you have a UPS called snoopy, your section header would be "[snoopy]".
# On a system called "doghouse", the line in your upsmon.conf to monitor
# it would look something like this:
#
# 	MONITOR snoopy@doghouse 1 upsmonuser mypassword master
#
# It might look like this if monitoring in slave mode:
#
# 	MONITOR snoopy@doghouse 1 upsmonuser mypassword slave
#
# Configuration directives
# ------------------------
#
# These directives are used by upsdrvctl only and should be specified outside
# of a driver definition:
#
#    maxretry: Optional.  Specify the number of attempts to start the driver(s),
#              in case of failure, before giving up. A delay of 'retrydelay' is
#              inserted between each attempt. Caution should be taken when using
#              this option, since it can impact the time taken by your system to
#              start.
#
#              The default is 1 attempt.
#
#  retrydelay: Optional.  Specify the delay between each restart attempt of the
#              driver(s), as specified by 'maxretry'. Caution should be taken
#              when using this option, since it can impact the time taken by your
#              system to start.
#
#              The default is 5 seconds.
# 
# These directives are common to all drivers that support ups.conf:
#
#  driver: REQUIRED.  Specify the program to run to talk to this UPS.  
#          apcsmart, bestups, and sec are some examples.
#
#    port: REQUIRED.  The serial port where your UPS is connected.  
#          /dev/ttyS0 is usually the first port on Linux boxes, for example.
#
# sdorder: optional.  When you have multiple UPSes on your system, you
#          usually need to turn them off in a certain order.  upsdrvctl
#          shuts down all the 0s, then the 1s, 2s, and so on.  To exclude
#          a UPS from the shutdown sequence, set this to -1.
#
#          The default value for this parameter is 0.
#
#  nolock: optional, and not recommended for use in this file.
#
#          If you put nolock in here, the driver will not lock the
#          serial port every time it starts.  This may allow other 
#          processes to seize the port if you start more than one by 
#          mistake.
#
#          This is only intended to be used on systems where locking
#          absolutely must be disabled for the software to work.
#
# maxstartdelay: optional.  This can be set as a global variable
#                above your first UPS definition and it can also be
#                set in a UPS section.  This value controls how long
#                upsdrvctl will wait for the driver to finish starting.
#                This keeps your system from getting stuck due to a
#                broken driver or UPS.
#
#                The default is 45 seconds.
#
# synchronous: optional.  The driver work by default in asynchronous
#              mode (i.e *synchronous=no*).  This means that all data
#              are pushed by the driver on the communication socket to
#              upsd (Unix socket on Unix, Named pipe on Windows) without
#              waiting for these data to be actually consumed.  With
#              some HW, such as ePDUs, that can produce a lot of data,
#              asynchronous mode may cause some congestion, resulting in
#              the socket to be full, and the driver to appear as not
#              connected.  By enabling the 'synchronous' flag
#              (value = 'yes'), the driver will wait for data to be
#              consumed by upsd, prior to publishing more.  This can be
#              enabled either globally or per driver.
#
#              The default is 'no' (i.e. asynchronous mode) for backward
#              compatibility of the driver behavior.
#
# Anything else is passed through to the hardware-specific part of
# the driver.
# 
# Examples
# --------
#
# A simple example for a UPS called "powerpal" that uses the blazer_ser
# driver on /dev/ttyS0 is:
#
# [powerpal]
#	driver = blazer_ser
#	port = /dev/ttyS0
#	desc = "Web server"
#
# If your UPS driver requires additional settings, you can specify them
# here.  For example, if it supports a setting of "1234" for the
# variable "cable", it would look like this:
# 
# [myups]
# 	driver = mydriver
#	port = /dev/ttyS1
#	cable = 1234
#	desc = "Something descriptive"
#
# To find out if your driver supports any extra settings, start it with
# the -h option and/or read the driver's documentation.

# Set maxretry to 3 by default, this should mitigate race with slow devices:
maxretry = 3

[salicru]
driver = blazer_usb
port = auto
desc = "Salicru SPS One"
# Network UPS Tools: example upsd configuration file
#
# This file contains access control data, you should keep it secure.
#
# It should only be readable by the user that upsd becomes.  See the FAQ.
#
# Each entry below provides usage and default value.

# =======================================================================
# MAXAGE <seconds>
# MAXAGE 15
#
# This defaults to 15 seconds.  After a UPS driver has stopped updating
# the data for this many seconds, upsd marks it stale and stops making
# that information available to clients.  After all, the only thing worse
# than no data is bad data.
#
# You should only use this if your driver has difficulties keeping
# the data fresh within the normal 15 second interval.  Watch the syslog
# for notifications from upsd about staleness.

# =======================================================================
# STATEPATH <path>
# STATEPATH /var/run/nut
#
# Tell upsd to look for the driver state sockets in 'path' rather
# than the default that was compiled into the program.

# =======================================================================
# LISTEN <address> [<port>]
# LISTEN 127.0.0.1 3493
# LISTEN ::1 3493
#
# This defaults to the localhost listening addresses and port 3493.
# In case of IP v4 or v6 disabled kernel, only the available one will be used.
#
# You may specify each interface you want upsd to listen on for connections,
# optionally with a port number.
#
# You may need this if you have multiple interfaces on your machine and
# you don't want upsd to listen to all interfaces (for instance on a
# firewall, you may not want to listen to the external interface).
#
# This will only be read at startup of upsd.  If you make changes here,
# you'll need to restart upsd, reload will have no effect.

# =======================================================================
# MAXCONN <connections>
# MAXCONN 1024
#
# This defaults to maximum number allowed on your system.  Each UPS, each
# LISTEN address and each client count as one connection.  If the server
# runs out of connections, it will no longer accept new incoming client
# connections.  Only set this if you know exactly what you're doing.

# =======================================================================
# CERTFILE <certificate file>
# CERTFILE /usr/local/ups/etc/upsd.pem
#
# When compiled with SSL support with OpenSSL backend,
# you can enter the certificate file here.
# The certificates must be in PEM format and must be sorted starting with
# the subject's certificate (server certificate), followed by intermediate
# CA certificates (if applicable_ and the highest level (root) CA. It should
# end with the server key. See 'docs/security.txt' or the Security chapter of
# NUT user manual for more information on the SSL support in NUT.
#
# See 'docs/security.txt' or the Security chapter of NUT user manual
# for more information on the SSL support in NUT.

# =======================================================================
# CERTPATH <certificate file or directory>
# CERTPATH /usr/local/ups/etc/cert/upsd
#
# When compiled with SSL support with NSS backend,
# you can enter the certificate path here.
# Certificates are stored in a dedicated database (splitted in 3 files).
# Specify the path of the database directory.
# 
# See 'docs/security.txt' or the Security chapter of NUT user manual
# for more information on the SSL support in NUT.

# =======================================================================
# CERTIDENT <certificate name> <database password>
# CERTIDENT "my nut server" "MyPasSw0rD"
#
# When compiled with SSL support with NSS backend,
# you can specify the certificate name to retrieve from database to
# authenticate itself and the password
# required to access certificate related private key.
# 
# See 'docs/security.txt' or the Security chapter of NUT user manual
# for more information on the SSL support in NUT.

# =======================================================================
# CERTREQUEST <certificate request level>
# CERTREQUEST REQUIRE
#
# When compiled with SSL support with NSS backend and client certificate
# validation (disabled by default, see 'docs/security.txt'),
# you can specify if upsd requests or requires client's' certificates.
# Possible values are :
#  - 0 to not request to clients to provide any certificate
#  - 1 to require to all clients a certificate
#  - 2 to require to all clients a valid certificate
# 
# See 'docs/security.txt' or the Security chapter of NUT user manual
# for more information on the SSL support in NUT.
# Network UPS Tools: Example upsd.users
#
# This file sets the permissions for upsd - the UPS network daemon.
# Users are defined here, are given passwords, and their privileges are
# controlled here too.  Since this file will contain passwords, keep it
# secure, with only enough permissions for upsd to read it.

# --------------------------------------------------------------------------

# Each user gets a section.  To start a section, put the username in
# brackets on a line by itself.  To set something for that user, specify
# it under that section heading.  The username is case-sensitive, so
# admin and AdMiN are two different users.
#
# Possible settings:
#
# password: The user's password.  This is case-sensitive.
#
# --------------------------------------------------------------------------
#
# actions: Let the user do certain things with upsd.  
# 
# Valid actions are:
#
# SET	- change the value of certain variables in the UPS
# FSD   - set the "forced shutdown" flag in the UPS
# 
# --------------------------------------------------------------------------
#
# instcmds: Let the user initiate specific instant commands.  Use "ALL"
# to grant all commands automatically.  There are many possible  
# commands, so use 'upscmd -l' to see what your hardware supports.  Here
# are a few examples:
#
# test.panel.start	- Start a front panel test
# test.battery.start	- Start battery test
# test.battery.stop	- Stop battery test
# calibrate.start	- Start calibration
# calibrate.stop	- Stop calibration
#
# --------------------------------------------------------------------------
#
# Example:
#
#	[admin]
#		password = mypass
#		actions = SET
#		instcmds = ALL
#

#
# --- Configuring for a user who can execute tests only
#
#	[testuser]
#		password  = pass
#		instcmds  = test.battery.start
#		instcmds  = test.battery.stop

#
# --- Configuring for upsmon
#
# To add a user for your upsmon, use this example:
#
#	[upsmon]
#		password  = pass
#		upsmon master
# or
#		upsmon slave
#
# The matching MONITOR line in your upsmon.conf would look like this:
#
# MONITOR myups@localhost 1 upsmon pass master	(or slave)

MAXAGE 15
STATEPATH /var/run/nut
LISTEN 127.0.0.1 3493
MAXCONN 1024

[admin]
        password = Ahoravasylacascas-somugriento
        actions = SET
        instcmds = ALL
# Network UPS Tools: example upsmon configuration
#
# This file contains passwords, so keep it secure.

# --------------------------------------------------------------------------
# RUN_AS_USER <userid>
#
# By default, upsmon splits into two processes.  One stays as root and
# waits to run the SHUTDOWNCMD.  The other one switches to another userid
# and does everything else.
#
# The default nonprivileged user is set at compile-time with
# 	'configure --with-user=...'.  
# 
# You can override it with '-u <user>' when starting upsmon, or just
# define it here for convenience.
#
# Note: if you plan to use the reload feature, this file (upsmon.conf)
# must be readable by this user!  Since it contains passwords, DO NOT
# make it world-readable.  Also, do not make it writable by the upsmon
# user, since it creates an opportunity for an attack by changing the
# SHUTDOWNCMD to something malicious.
#
# For best results, you should create a new normal user like "nutmon",
# and make it a member of a "nut" group or similar.  Then specify it
# here and grant read access to the upsmon.conf for that group.
#
# This user should not have write access to upsmon.conf.
#
# RUN_AS_USER nut

# --------------------------------------------------------------------------
# MONITOR <system> <powervalue> <username> <password> ("master"|"slave")
#
# List systems you want to monitor.  Not all of these may supply power
# to the system running upsmon, but if you want to watch it, it has to
# be in this section.
# 
# You must have at least one of these declared.
#
# <system> is a UPS identifier in the form <upsname>@<hostname>[:<port>]
# like ups@localhost, su700@mybox, etc.
# 
# Examples:
# 
#  - "su700@mybox" means a UPS called "su700" on a system called "mybox"
#
#  - "fenton@bigbox:5678" is a UPS called "fenton" on a system called
#    "bigbox" which runs upsd on port "5678".
#
# The UPS names like "su700" and "fenton" are set in your ups.conf
# in [brackets] which identify a section for a particular driver.
#
# If the ups.conf on host "doghouse" has a section called "snoopy", the
# identifier for it would be "snoopy@doghouse".
#
# <powervalue> is an integer - the number of power supplies that this UPS 
# feeds on this system.  Most computers only have one power supply, so this 
# is normally set to 1.  You need a pretty big or special box to have any 
# other value here.
#
# You can also set this to 0 for a system that doesn't supply any power,
# but you still want to monitor.  Use this when you want to hear about
# changes for a given UPS without shutting down when it goes critical,
# unless <powervalue> is 0.
#
# <username> and <password> must match an entry in that system's
# upsd.users.  If your username is "monmaster" and your password is 
# "blah", the upsd.users would look like this:
#
#	[monmaster]
#		password  = blah
#		upsmon master 	(or slave)
# 
# "master" means this system will shutdown last, allowing the slaves
# time to shutdown first.
#
# "slave" means this system shuts down immediately when power goes critical.
#
# Examples: 
#
# MONITOR myups@bigserver 1 monmaster blah master
# MONITOR su700@server.example.com 1 upsmon secretpass slave
# MONITOR myups@localhost 1 upsmon pass master	(or slave)

# --------------------------------------------------------------------------
# MINSUPPLIES <num>
#
# Give the number of power supplies that must be receiving power to keep
# this system running.  Most systems have one power supply, so you would
# put "1" in this field.
#
# Large/expensive server type systems usually have more, and can run with
# a few missing.  The HP NetServer LH4 can run with 2 out of 4, for example,
# so you'd set that to 2.  The idea is to keep the box running as long
# as possible, right?
#
# Obviously you have to put the redundant supplies on different UPS circuits
# for this to make sense!  See big-servers.txt in the docs subdirectory
# for more information and ideas on how to use this feature.

MINSUPPLIES 1

# --------------------------------------------------------------------------
# SHUTDOWNCMD "<command>"
#
# upsmon runs this command when the system needs to be brought down.
#
# This should work just about everywhere ... if it doesn't, well, change it.

SHUTDOWNCMD "/sbin/shutdown -h +0"

# --------------------------------------------------------------------------
# NOTIFYCMD <command>
#
# upsmon calls this to send messages when things happen
#
# This command is called with the full text of the message as one argument.
# The environment string NOTIFYTYPE will contain the type string of
# whatever caused this event to happen.
#
# Note that this is only called for NOTIFY events that have EXEC set with
# NOTIFYFLAG.  See NOTIFYFLAG below for more details.
#
# Making this some sort of shell script might not be a bad idea.  For more
# information and ideas, see docs/scheduling.txt
#
# Example:
# NOTIFYCMD /bin/notifyme

# --------------------------------------------------------------------------
# POLLFREQ <n> 
#
# Polling frequency for normal activities, measured in seconds.
#
# Adjust this to keep upsmon from flooding your network, but don't make 
# it too high or it may miss certain short-lived power events.

POLLFREQ 5

# --------------------------------------------------------------------------
# POLLFREQALERT <n>
#
# Polling frequency in seconds while UPS on battery.
#
# You can make this number lower than POLLFREQ, which will make updates
# faster when any UPS is running on battery.  This is a good way to tune 
# network load if you have a lot of these things running.  
#
# The default is 5 seconds for both this and POLLFREQ.

POLLFREQALERT 5

# --------------------------------------------------------------------------
# HOSTSYNC - How long upsmon will wait before giving up on another upsmon
#
# The master upsmon process uses this number when waiting for slaves to
# disconnect once it has set the forced shutdown (FSD) flag.  If they
# don't disconnect after this many seconds, it goes on without them.
#
# Similarly, upsmon slave processes wait up to this interval for the 
# master upsmon to set FSD when a UPS they are monitoring goes critical -
# that is, on battery and low battery.  If the master doesn't do its job,
# the slaves will shut down anyway to avoid damage to the file systems.
#
# This "wait for FSD" is done to avoid races where the status changes
# to critical and back between polls by the master.

HOSTSYNC 15

# --------------------------------------------------------------------------
# DEADTIME - Interval to wait before declaring a stale ups "dead"
#
# upsmon requires a UPS to provide status information every few seconds
# (see POLLFREQ and POLLFREQALERT) to keep things updated.  If the status
# fetch fails, the UPS is marked stale.  If it stays stale for more than
# DEADTIME seconds, the UPS is marked dead.
#
# A dead UPS that was last known to be on battery is assumed to have gone
# to a low battery condition.  This may force a shutdown if it is providing
# a critical amount of power to your system.
#
# Note: DEADTIME should be a multiple of POLLFREQ and POLLFREQALERT.
# Otherwise you'll have "dead" UPSes simply because upsmon isn't polling
# them quickly enough.  Rule of thumb: take the larger of the two
# POLLFREQ values, and multiply by 3.

DEADTIME 15

# --------------------------------------------------------------------------
# POWERDOWNFLAG - Flag file for forcing UPS shutdown on the master system
#
# upsmon will create a file with this name in master mode when it's time
# to shut down the load.  You should check for this file's existence in
# your shutdown scripts and run 'upsdrvctl shutdown' if it exists.
#
# See the config-notes.txt file in the docs subdirectory for more information.
# Refer to the section:
# [[UPS_shutdown]] "Configuring automatic shutdowns for low battery events"
# or refer to the online version.

POWERDOWNFLAG /etc/killpower

# --------------------------------------------------------------------------
# NOTIFYMSG - change messages sent by upsmon when certain events occur
#
# You can change the default messages to something else if you like.
#
# NOTIFYMSG <notify type> "message"
#
# NOTIFYMSG ONLINE	"UPS %s on line power"
# NOTIFYMSG ONBATT	"UPS %s on battery"
# NOTIFYMSG LOWBATT	"UPS %s battery is low"
# NOTIFYMSG FSD		"UPS %s: forced shutdown in progress"
# NOTIFYMSG COMMOK	"Communications with UPS %s established"
# NOTIFYMSG COMMBAD	"Communications with UPS %s lost"
# NOTIFYMSG SHUTDOWN	"Auto logout and shutdown proceeding"
# NOTIFYMSG REPLBATT	"UPS %s battery needs to be replaced"
# NOTIFYMSG NOCOMM	"UPS %s is unavailable"
# NOTIFYMSG NOPARENT	"upsmon parent process died - shutdown impossible"
#
# Note that %s is replaced with the identifier of the UPS in question.
#
# Possible values for <notify type>:
#
# ONLINE   : UPS is back online
# ONBATT   : UPS is on battery
# LOWBATT  : UPS has a low battery (if also on battery, it's "critical")
# FSD      : UPS is being shutdown by the master (FSD = "Forced Shutdown")
# COMMOK   : Communications established with the UPS
# COMMBAD  : Communications lost to the UPS
# SHUTDOWN : The system is being shutdown
# REPLBATT : The UPS battery is bad and needs to be replaced
# NOCOMM   : A UPS is unavailable (can't be contacted for monitoring)
# NOPARENT : The process that shuts down the system has died (shutdown impossible)

# --------------------------------------------------------------------------
# NOTIFYFLAG - change behavior of upsmon when NOTIFY events occur
#
# By default, upsmon sends walls (global messages to all logged in users)
# and writes to the syslog when things happen.  You can change this.
#
# NOTIFYFLAG <notify type> <flag>[+<flag>][+<flag>] ...
#
# NOTIFYFLAG ONLINE	SYSLOG+WALL
# NOTIFYFLAG ONBATT	SYSLOG+WALL
# NOTIFYFLAG LOWBATT	SYSLOG+WALL
# NOTIFYFLAG FSD	SYSLOG+WALL
# NOTIFYFLAG COMMOK	SYSLOG+WALL
# NOTIFYFLAG COMMBAD	SYSLOG+WALL
# NOTIFYFLAG SHUTDOWN	SYSLOG+WALL
# NOTIFYFLAG REPLBATT	SYSLOG+WALL
# NOTIFYFLAG NOCOMM	SYSLOG+WALL
# NOTIFYFLAG NOPARENT	SYSLOG+WALL
#
# Possible values for the flags:
#
# SYSLOG - Write the message in the syslog 
# WALL   - Write the message to all users on the system
# EXEC   - Execute NOTIFYCMD (see above) with the message
# IGNORE - Don't do anything
#
# If you use IGNORE, don't use any other flags on the same line.

# --------------------------------------------------------------------------
# RBWARNTIME - replace battery warning time in seconds
#
# upsmon will normally warn you about a battery that needs to be replaced
# every 43200 seconds, which is 12 hours.  It does this by triggering a
# NOTIFY_REPLBATT which is then handled by the usual notify structure
# you've defined above.
# 
# If this number is not to your liking, override it here.

RBWARNTIME 43200

# --------------------------------------------------------------------------
# NOCOMMWARNTIME - no communications warning time in seconds
#
# upsmon will let you know through the usual notify system if it can't
# talk to any of the UPS entries that are defined in this file.  It will
# trigger a NOTIFY_NOCOMM by default every 300 seconds unless you 
# change the interval with this directive.

NOCOMMWARNTIME 300

# --------------------------------------------------------------------------
# FINALDELAY - last sleep interval before shutting down the system
#
# On a master, upsmon will wait this long after sending the NOTIFY_SHUTDOWN
# before executing your SHUTDOWNCMD.  If you need to do something in between
# those events, increase this number.  Remember, at this point your UPS is 
# almost depleted, so don't make this too high.
#
# Alternatively, you can set this very low so you don't wait around when
# it's time to shut down.  Some UPSes don't give much warning for low
# battery and will require a value of 0 here for a safe shutdown.
#
# Note: If FINALDELAY on the slave is greater than HOSTSYNC on the master,
# the master will give up waiting for the slave to disconnect.

FINALDELAY 5

# --------------------------------------------------------------------------
# CERTPATH - path to certificates (database directory or directory with CA's)
#
# When compiled with SSL support, you can enter the certificate path here.
#
# With NSS:
# Certificates are stored in a dedicated database (splitted in 3 files).
# Specify the path of the database directory.
# 
# CERTPATH /etc/nut/cert/upsmon
#
# With OpenSSL:
# Directory containing CA certificates in PEM format, used to verify
# the server certificate presented by the upsd server. The files each
# contain one CA certificate. The files are looked up by the CA subject
# name hash value, which must hence be available.
#
# CERTPATH /usr/ssl/certs
# 
# See 'docs/security.txt' or the Security chapter of NUT user manual
# for more information on the SSL support in NUT.

# --------------------------------------------------------------------------
# CERTIDENT - self certificate name and database password
# CERTIDENT <certificate name> <database password>
#
# When compiled with SSL support with NSS, you can specify the certificate
# name to retrieve from database to authenticate itself and the password
# required to access certificate related private key.
#
# CERTIDENT "my nut monitor" "MyPasSw0rD"
# 
# See 'docs/security.txt' or the Security chapter of NUT user manual
# for more information on the SSL support in NUT.

# --------------------------------------------------------------------------
# CERTHOST - security properties for an host
# CERTHOST <hostname> <certificate name> <certverify> <forcessl>
#
# When compiled with SSL support with NSS, you can specify security directive
# for each server you can contact.
# Each entry maps server name with the expected certificate name and flags
# indicating if the server certificate is verified and if the connection
# must be secure.
#
# CERTHOST localhost "My nut server" 1 1
#
# See 'docs/security.txt' or the Security chapter of NUT user manual
# for more information on the SSL support in NUT.

# --------------------------------------------------------------------------
# CERTVERIFY - make upsmon verify all connections with certificates
# CERTVERIFY 1
#
# When compiled with SSL support, make upsmon verify all connections with 
# certificates.
# Without this, there is no guarantee that the upsd is the right host.
# Enabling this greatly reduces the risk of man in the middle attacks.
# This effectively forces the use of SSL, so don't use this unless
# all of your upsd hosts are ready for SSL and have their certificates
# in order.
# When compiled with NSS support of SSL, can be overriden for host 
# specified with a CERTHOST directive.


# --------------------------------------------------------------------------
# FORCESSL - force upsmon to use SSL
# FORCESSL 1
#
# When compiled with SSL, specify that a secured connection must be used
# to communicate with upsd.
# If you don't use 'CERTVERIFY 1', then this will at least make sure
# that nobody can sniff your sessions without a large effort.  Setting
# this will make upsmon drop connections if the remote upsd doesn't
# support SSL, so don't use it unless all of them have it running.
# When compiled with NSS support of SSL, can be overriden for host 
# specified with a CERTHOST directive.

MONITOR salicru@127.0.0.1:3493 1 admin Localhost1977 master

#NOTIFYCMD /usr/local/ups/bin/notifyme.sh 

NOTIFYMSG ONLINE        "UPS %s on line power"
NOTIFYMSG ONBATT        "UPS %s on battery"
NOTIFYMSG LOWBATT       "UPS %s battery is low"
NOTIFYMSG FSD           "UPS %s: forced shutdown in progress"
NOTIFYMSG COMMOK        "Communications with UPS %s established"
NOTIFYMSG COMMBAD       "Communications with UPS %s lost"
NOTIFYMSG SHUTDOWN      "Auto logout and shutdown proceeding"
NOTIFYMSG REPLBATT      "UPS %s battery needs to be replaced"
NOTIFYMSG NOCOMM        "UPS %s is unavailable"
NOTIFYMSG NOPARENT      "upsmon parent process died - shutdown impossible"

NOTIFYFLAG ONLINE       SYSLOG+WALL
NOTIFYFLAG ONBATT       SYSLOG+WALL
NOTIFYFLAG LOWBATT      SYSLOG+WALL
NOTIFYFLAG FSD          SYSLOG+WALL
NOTIFYFLAG COMMOK       SYSLOG+WALL
NOTIFYFLAG COMMBAD      SYSLOG+WALL
NOTIFYFLAG SHUTDOWN     SYSLOG+WALL
NOTIFYFLAG REPLBATT     SYSLOG+WALL
NOTIFYFLAG NOCOMM       SYSLOG+WALL
NOTIFYFLAG NOPARENT     SYSLOG+WALL
# Network UPS Tools - upssched.conf sample file
#
# ============================================================================
#
# CMDSCRIPT <scriptname>
#
# This script gets called to invoke commands for timers that trigger.
# It is given a single argument - the <timername> in your
# AT ... START-TIMER defines.
#
# *** This must be defined *before* the first AT line.  Otherwise the
#     program will complain and exit without doing anything.
#
# A shell script with a big case..esac construct should work nicely for this.
# An example has been provided to help you get started.

CMDSCRIPT /bin/upssched-cmd

# ============================================================================
#
# PIPEFN <filename>
#
# This sets the file name of the FIFO that will pass communications between
# processes to start and stop timers.  This should be set to some path where
# normal users can't create the file, due to the possibility of symlinking
# and other evil.
#
# Note: if you are running Solaris or similar, the permissions that 
# upssched sets on this file *are not enough* to keep you safe.  If
# your OS ignores the permissions on a FIFO, then you MUST put this in
# a protected directory!
#
# Note 2: by default, upsmon will run upssched as whatever user you have
# defined with RUN_AS_USER in upsmon.conf.  Make sure that user can
# create files and write to files in the path you use for PIPEFN and
# LOCKFN.
#
# My recommendation: create a special directory for upssched, make it
# owned by your upsmon user, then use it for both.
#
# This is commented out by default to make you visit this file and think
# about how your system works before potentially opening a hole.
#
# PIPEFN /run/nut/upssched/upssched.pipe

# ============================================================================
#
# LOCKFN <filename>
#
# REQUIRED.  This was added after version 1.2.1.
#
# upssched needs to be able to create this filename in order to avoid
# a race condition when two events are dispatched from upsmon at nearly
# the same time.  This file will only exist briefly.  It must not be
# created by any other process.
#
# You should put this in the same directory as PIPEFN.
#
# LOCKFN /run/nut/upssched/upssched.lock

# ============================================================================
#
# AT <notifytype> <upsname> <command>
#
# Define a handler for a specific event <notifytype> on UPS <upsname>.
#
# <upsname> can be the special value * to apply this handler to every
# possible value of <upsname>.
#
# Run the command <command> via your CMDSCRIPT when it happens. 
#
# Note that any AT that matches both the <notifytype> and the <upsname> 
# for the current event will be used.

# ============================================================================
#
# Possible AT commands
#
# - START-TIMER <timername> <interval>
#
#   Start a timer called <timername> that will trigger after <interval>
#   seconds, calling your CMDSCRIPT with <timername> as the first
#   argument.
#
#   Example:
#   Start a timer that'll execute when any UPS (*) has been gone 10 seconds
#
#   AT COMMBAD * START-TIMER upsgone 10

#   -----------------------------------------------------------------------
#
# - CANCEL-TIMER <timername> [cmd]
#
#   Cancel a running timer called <timername>, if possible. If the timer
#   has passed then pass the optional argument <cmd> to CMDSCRIPT.
#
#   Example:
#   If a specific UPS (myups@localhost) comes back online, then stop the 
#   timer before it triggers
# 
#   AT COMMOK myups@localhost CANCEL-TIMER upsgone

#   -----------------------------------------------------------------------
#
# - EXECUTE <command>
#
#   Immediately pass <command> as an argument to CMDSCRIPT.
#
#   Example:
#   If any UPS (*) reverts to utility power, then execute
#   'ups-back-on-line' via CMDSCRIPT.
#
#   AT ONLINE * EXECUTE ups-back-on-line

Dejo por último los distintos artículos/tutoriales en español que he consultado para aprender a configurar lo:

  • https://www.jormc.es/tutoriales/administracion-basica-del-sai-salicru-spsone-900va-con-nut/
  • https://www.jormc.es/2014/05/11/raspi-conectando-un-sai-salicru-sps-one-900va/